J type fuse links 415v electricity supply distribution fuse links bs88 j type electricity supply fuse links jhu, jpu, jsu. However, it is important that only the protection device immediately upstream of a fault trips if a fault. Switchtec ltd, brooms road, stone business park, stone staffordshire st15 0sh phone. These are manually operated switches and the making and breaking is. Red spot fingersafe bs88 hrc fuse holder, blk, 200a, back stud connect download datasheet. Reliance controls 200amp indoor generatorready load center w watt meters. In addition, a pushon adapter and microswitch attachment are available, to provide remote indication.
Nominal rating a fuses circuitbreakers to bs 3871 or bs en 60898 or rcb0s to bs en 61009 bs 88 gg parts 2 and 6 bs 61 or bs 62 bs 3036 bs 882 fuse systems e bolted and g clip in bs883 fuse. The fuses interrupting rating is typically at least equal to, or in many cases greater. We also have fusible manual transfer switch based solutions, a reliable and time tested technology. Buy cooper bussmann 200a british standard fuse, b2, 415v ac, 111mm dd200m250. Fuses are safety devices used to interrupt the current when the electrical current reaches too high a level, or when a short circuit occurs. Bs88, iec269 industrial hrc fuse links offset bolted tags 415v ac 125200 amps deo offset bolted tag bussmann division cooper u. Lawson j type fuse links are for circuit protection of a. Advantages high level performance high breaking capacity 120 ka at 500 v, 80 ka at 690 v. Neutral enclosed bs88 switch fuses ip65 ip65 stainless steel enclosed door interlocked switch fuses 125200a. Bs 88 cartridge fuses for voltages up to and including v a. Run your backup generator with the ge 200 amp 240volt nonfused emergency power transfer switch. Size b1 to b4, c1 to c3 and d1 centre bolted tag fuse links. The bussmann standard range of high breaking capacity fuse links for low voltage industrial and general purpose applications meet the requirements of bs88 and iec60269.
Ge 200 amp 240volt nonfused emergency power transfer switch. For use with 6 250 awgkcmil copper or aluminum lug wire, this transfer switch is rated for safety with a ul listing and an ansi certification. Introduction british bs 88 contents fuse amp volts range page 240 6. We make it easy to find the exact bs88 fuse you need. Suitable circuit protection devices must be fitted to protect installed electrical equipment and people. Eaton dt224fgk safety switch, double throw, heavy duty, 200a. Generac power systems find my manual, parts list, and. Red spot fingersafe bs88 hrc fuse holder, black, 200a, front connect. Solid link a4 tfp fuse rated 200a manufactured by mersen lawson box qty 10. Rs pro 200a british standard fuse, b2, 415v ac, 111mm. Utility applications to bs88 bs 61 house service cutout fuse links. Abb of series fuse links are specifically designed to react to temperature rise and as such limit current very reliably.
Fuserbloc are manually operated multipolar fuse combination switches. Remotely operated transfer switch atys d m 40 160amp atys d 125 3200amp atys r 125 3200amp wohner iec fuse holders cylindrical nh fuseswitch disconnectors nh fusebases din fuses bussmann bs88 fuseholders bs88 hrc fuses. Bussmann nitd20 bussmann fuse bs88 20a 550vac part of slotted tag fuses, distributed by kempston controls. Units are fitted with hrc fuselinks of maximum rating but will accept fuselinks of a lower rating. Ronk 7225 fused disconnect doublethrow transfer switches are service entrance rated for 200a 1phase 120240vac applications. Eaton dt224fgk safety switch, double throw, heavy duty, 200a, 240vac, nema 1 200 amp, 2pole, heavy duty safety switch, fusible without neutral, 240 vac, 250 vdc, nema 1. Glasgow fuseswitchdisconnectors and switchdisconnectors are supplied with fuselinks or switchlinks fitted. Electricity supply fuse links with wedge connections to iec 602692, bs 882. Competitors products may differ from bussmann series products, therefore it is recommended that each application is checked for. Socomec industrial fuses protect installations and people against overcurrents for any low voltage electrical circuit. Bussmann by eaton rs200h red spot fingersafe bs88 hrc.
Offna4gg200 abb 200a bolted tag fuse, a4, 415v, 94mm rs. Integrating protection components and power interconnection solutions for function and performance. Bs88 fuseholders bs88 hrc fuses iec cylindrical fuses. Est are normally processed the same day next business day for weekend orders. Neutral enclosed bs88 switch fuses ip65 ip66 grpc enclosed door interlocked switch fuses 125400a. J type fuse links 415v electricity supply distribution. Electric screw driver manual secrew driver max torque setting 3. Fuses upstream circuit breakers downstream table b. These requirements cover manual, starter, controllers, and overload dont. Psi control solutions offers a complete line of nonfusible manual transfer switches from 303000 amps. All units have retractable operating handles which drive overcentre mechanisms incorporating powerful operating springs. Buy cooper bussmann 200a british standard fuse, b2, 415v ac, 111mm dd200.
Bs88 fuseholders bs88 hrc fuses iec cylindrical fuses uksolenoid control switches. J type fuse links 415v electricity supply distribution fuse. Reliance controls 200amp outdoor manual transfer panel. Didnt have my osg to hand earlier but quite sadly knew the page no. A fuse is a device that, by the fusion of one or more of its specially designed and proportioned components, opens the circuit in which it is inserted and breaks the current when this exceeds a given value for a sufficient time. Ulcsa low voltage general purpose fuses, fuseholders and. Bs88 ref b1 to b4, c1 to c3 and d1 alternative fuse links.
Fuse blocks are also available for most applications. Psi manual transfer switch w rotary switch 2003000 amps. Scattergood and johnson are specialist distributors to industry in the uk supplying equipment in to the following areas automation,safety systems,fluidpneumatic control,switchgear distributors,sensing and switching,motor control automation and cable management. Mersen offers a wide range of products and solutions covering all aspects of energy safety and power management. For immediate assistance please use our online chat.
In other words the 200 a fuse should only be subjected to a maximum. To search our extensive online database, simply enter the part number, or search by keyword. Bs88 fuses 200a b2 415v bs88 fuse switchtec ltd website. Bussmann series bs88 fuse links cross reference important notice. Designed to mount on the outside of a house or building next to the utility meter, it connects to the load center indoors via sub feed lugs. Fuse protected shortcircuit withstand bs88din ka rms prospective. Bs 88 industrial fuses gg and gm curves 146 gg and gm fuselink selection 0,75 1 2 6 4 1,1 1,5 2,5 10 6 1,5 2 3,5 10 6 2,2 3 5 16 10 346,5 20 16 4582520m25 16 5,5 7,5 11 32 20m32 20 7,5 10 14 40 32m40 25 20m25 10,5 19 50 32m50 32 20m32 11 15 21 50 32m50 32 15 20 28 63 32m63 40 32m40 18,5 25 35 80 63m80 50 22 30. Manual transfer switch generator manual transfer switch. Homelink 50 amp upgradeable manual transfer switch. Complete isolation of the fuse with double breaking per pole top and bottom of fuse. Bs88 fuse holders bs88 fuse holders for offset blade tag fuse linksbs88 fuse holders bs88 fuse holders bs88 fuse holders for offset blade tag fuse links 25 dimensions for f1 fuse range bff63f2 front wire connected bbb63f2 back stud connected bfb63f2 frontback busbar stud connected 89 28. Blue dot is the brand name of the ferraz shawmuts bs88 general purpose fuse and fusegear range of products. Mersen ensures the safe, reliable, and efficient distribution of electrical power throughout facilities and systems. Ltd burtononthewolds leicestershire, le12 5th united kingdom tel.
By using advanced fuse technology the current ratngs up to 400a have compact dimensions but still within the standardised dimensional and performance requirements. Reliance controls 200amp indoor generatorready load center. Psi manual transfer switches are offered in 603000 amps with enclosure rating options including nema 1, nema 3r, and nema 4x. If your needs are for a service entrance rated manual transfer switch in a nema 3r enclosure or a nema 4x 316 stainless steel enclosure, psi. Find out more about the range of fuses offered by socomec. Dd200 cooper bussmann 200a british standard fuse, b2, 415v. Ulcsa low voltage general purpose fuses, fuseholders and power distribution blocks look for a product which product fuse bases fuse holders fuse systems fuses iec fuse switch disconnectors lowvoltage switches surge protection wiring management custom products. Dd200m250 cooper bussmann 200a british standard fuse, b2.
The comparative catalogue numbers shown on this guide are derived from the latest available published information from the manufacturers shown. Voltimum discrimination of protection devices what is it about. We are also contactable by email if your enquiry is out. Maximum measured values of earth fault loop impedance z s the table below provides maximum values of zs for fuses and circuit breakers. Worlds leading supplier of fuses and fusible protection systems. A range of british standard fuse links specifically designed for the protection of general industrial applications e.
U imp according iec 602691 8 kv specifications for f1 fuse links for f2 fuse links. Standard features good peak letthrough current limitation 1. Replacement fuse links for 250v ren and 600v res renewable fuses in ratings from 1600 amps lkn lks. They make and break on load and provide safety isolation and protection against overcurrent for any low voltage electrical circuit. Low power loss, typically 20% lower than the requirements of bs88. The products shown on this cross reference chart are a selection of some of the most commonly used low voltage fuse links. Glasgow fuse switchdisconnectors and switchdisconnectors are supplied with fuselinks or switchlinks fitted.
Ronk 7225 fused disconnect transfer switch 1ph, 200a. Dd200 cooper bussmann 200a british standard fuse, b2. In north america, fuses are required to clear only their rated voltage. Glasgow fuseswitchdisconnectors, switchdisconnectors. Accessories tripindicator fuses are available for use in parallel with the main fuse. The switch component is labeled ul1008 through 100 amps through 1200 amps. Bs88 fuse holders bs88 fuse holders for offset blade tag fuse linksbs88 fuse holders bs88 fuse holders. Eaton dt224fgk safety switch, double throw, heavy duty. All bussmann series british style fuses are tested to iec 269. Orders for bs88 fuses and other standard, instock items placed by 4 p. This standard requires a test voltage which is 5% higher than the rated voltage. Eaton manufactures one of the most comprehensive range of low voltage fuse links.
Maximum measured values of earth fault loop impedance z. A range of centre tagged bs fuse links in sizes b1 to b4, c1 to c3 and d1 specifically designed for the protection of general industrial. Bs88 industrial fuselinks fuse protection from 2 to 1250 a socomec industrial fuses protect installations and people against overcurrents for any low voltage electrical circuit. Indicator fuses can be attached to the associated fuselink, or mounted separately in panelmounted fuseclips. Bs 88 industrial fuses gg and gm curves 143 applications power cable protection distribution panel protection. All cooper bussmann british style fuses are tested to iec. Current rated voltage rated voltage fixing centres interrupting box rating ac dc mm rating quantity 125n11660 125 160n11660 160 200n11660 200 250n11660 250 315n11660 315. Bussmann nitd20 bussmann fuse bs88 20a 550vac kempston controls. Current rated voltage rated voltage fixing centres interrupting box rating ac dc mm rating quantity 125n11660 125 160n11660 160 200n11660 200 250n11660 250. Bs 88 industrial fuses gg and gm curves 146 gg and gm fuse link selection 0,75 1 2 6 4 1,1 1,5 2,5 10 6 1,5 2 3,5 10 6 2,2 3 5 16 10 346,5 20 16 4582520m25 16 5,5 7,5 11 32 20m32 20 7,5 10 14 40 32m40 25 20m25 10,5 19 50 32m50 32 20m32 11 15 21 50 32m50 32 15 20 28 63 32m63 40 32m40 18,5 25 35 80 63m80 50 22 30. Bussmann series ac bs88 centre bolted tags data sheet no. Fuse switches 20 1250a manual changeover switches sircover 125 3200a ats automatic transfer switch. If you cannot find the fuse link you need please contact eatons technical application support for assistance. For help with safety switch, double throw, heavy duty, 200a, 240vac, nema 1 from eaton.
Socomec fuses are safety devices that allow the current to be interrupted whenever the current is too high. This emergency power transfer switch offers a nema type3r metal enclosure for outdoor use. Bussmann by eaton rs200p red spot fingersafe bs88 hrc. Nh din dual indication fuse links nh din dual indication fuse links. The overall package will be assembled and labeled in accordance with ul 1008 for non fusible nonservice. Size b1 to b4, c1 to c3 and d1 centre bolted tag fuse. These devices are reliable and safe, and can be used in industry motor protection, cables and equipment as well as in power electronics protection of inverters and variable speed drives. Bussmann tkm250 bussmann ge 250a 660v ac 460v dc bs88 fuse part of bs88 fuses, distributed by kempston controls.